How To Drain A Pressure Tank: A Complete Step-by-Step Maintenance Guide

How To Drain A Pressure Tank: A Complete Step-by-Step Maintenance Guide

How to Drain a Water Heater Safely and Effectively • strongeru.com

Draining a well pressure tank requires completely cutting power to the pump, isolating the plumbing system, and gravity-feeding trapped water out through the lower drain valve. Performing this routine maintenance annually eliminates waterlogged bladders, prevents pump short-cycling, and restores proper drawdown capacity to your private water system.

Pre-Operation & Equipment Checklist

Maintaining a private well system involves understanding the mechanical relationship between your submersible or jet pump, the pressure switch, and the pressure tank. Over time, waterlogged pressure tanks—caused by a failing internal bladder, a compromised air volume control, or air leaks at the Schrader valve—force your well pump to rapidly cycle on and off every time a faucet is opened. This excessive cycling burns out pump motors prematurely, leading to costly replacements.

Before beginning the drainage process, gather the necessary tools and verify system parameters to ensure a safe, efficient workflow.



  • Essential Gear, Tools, and Materials:

    • Standard garden hose (long enough to reach a safe drainage slope or floor drain)
    • Adjustable wrench or tongue-and-groove pliers
    • Pressure gauge (standard tire pressure gauge with a reading range of 0 to 100 PSI)
    • Bicycle pump or portable air compressor
    • Plumber's tape (PTFE tape) for thread sealing if valves are removed
    • Bucket and towels for minor residual spills
  • Mandatory Prerequisite Knowledge & Standards:

    • Locate the electrical breaker supplying 230V or 115V power to the well pump. Never drain a tank while the pump is energized, as running a dry or deadheaded pump destroys internal components.
    • Understand your system's cut-in and cut-off pressures. Standard residential systems typically operate on a 30/50 PSI or 40/60 PSI differential.
  • Estimated Budget & Duration Benchmarks:

    • Total time required: 30 to 45 minutes.
    • Financial cost: Zero dollars if tools are on hand; minor cost if replacing a faulty Schrader valve core or pressure gauge.

Step-by-Step Drainage and Air Recharge Workflow



Step 1: Disconnect Power to the Well Pump

Locate your home's main electrical service panel or the dedicated pressure switch disconnect box, and flip the breaker serving the well pump to the off position. Shutting off power is critical because draining the tank while the system is live will cause the pressure switch to drop below the cut-in threshold, triggering the pump to run continuously against an empty tank and potentially burning out the motor windings.

Warning: Never rely solely on the toggle switch of a pressure switch if it features one. Always trip the dedicated circuit breaker to completely isolate electrical current from the pump motor control box.



Step 2: Shut Off the Water Supply and Open Faucets

Locate the main incoming water shut-off valve situated immediately before the pressure tank and turn it clockwise to the closed position. Next, walk to the lowest point in your home, such as a basement laundry sink, a utility room spigot, or an outdoor hose bib, and open the faucet fully. Open a few upstairs faucets as well to introduce air into the plumbing lines and facilitate complete gravity drainage.



Step 3: Attach a Drainage Hose and Open the Tank Drain Valve

Find the boiler drain or sediment faucet located at the bottom tee fitting of the pressure tank or directly on the tank base. Thread one end of your standard garden hose securely onto this drain valve, and place the discharge end in a floor drain, sump pit, or outside away from building foundations. Open the drain valve completely using an adjustable wrench if needed, allowing all stored water within the tank and household supply lines to empty out.

Pro-Tip: Watch the discharge stream coming out of the garden hose. When the water stops flowing entirely, leave the drain valve open for the duration of the air-charging phase to push out any lingering moisture trapped in the bottom of the vessel.



Step 4: Check and Correct Air Pressure in the Bladder

Locate the Schrader valve on top of the pressure tank, which looks identical to a standard automobile tire valve stem. Remove the plastic protective cap and use your digital or analog tire pressure gauge to check the internal air pressure of the tank's bladder chamber while the water is actively draining out the bottom. The correct air pre-charge must be measured and set precisely two PSI below your pump's cut-in pressure setting. For example, if your pressure switch is set to 30/50 PSI, the tank air pressure must read exactly 28 PSI.



Step 5: Adjust Air Pressure via Compressor or Bicycle Pump

If your pressure reading is lower than the target benchmark, attach a portable air compressor or manual bicycle pump to the Schrader valve and add air until you reach the correct PSI. If water forcefully sprays out of the Schrader valve when you press the core pin, the internal rubber bladder has ruptured. A ruptured bladder cannot hold air, meaning you must replace the entire pressure tank immediately.



Step 6: Close Valves, Pressurize, and Restart the System

Once the tank is completely drained of water and the correct air pre-charge is verified, close the tank drain valve tightly and disconnect the garden hose. Close all open household faucets that you opened earlier in the process. Slowly open the main water supply valve from the well to let water re-enter the pressure tank and household plumbing network. Finally, return to the electrical panel and switch the well pump breaker back to the ON position. Monitor the pressure gauge on the tank as it climbs to ensure the pump cuts off correctly at the designated high-pressure limit.


Bladder Type Pressure Tank - Inspection Gallery - InterNACHI®

Bladder Type Pressure Tank - Inspection Gallery - InterNACHI®

Pressure Tank Specifications and Operating Parameters



Tank Parameter Standard Residential Setting High-Capacity Commercial Setting Action Threshold for Replacement
Operating Pressure 30/50 PSI or 40/60 PSI 50/70 PSI or customized ranges Exceeds local plumbing structural ratings
Air Pre-Charge Target 2 PSI below cut-in (e.g., 28 PSI) 2 PSI below cut-in (e.g., 48 PSI) Inability to hold air pressure over 30 days
Tank Capacity 20 to 86 gallons (Bladder style) 120 to 500+ gallons Permanent internal bladder separation
Maintenance Interval Once per year Semi-annually Constant pump short-cycling despite re-charge

Common System Failures and Field Fixes



  • Root Cause: Water continuously spraying out of the Schrader valve when checking air pressure.

    • Actionable Fix: The internal rubber diaphragm or butyl bladder has torn, mixing water and air chambers. You cannot repair a ruptured bladder; you must uninstall the tank and install a replacement unit matching your system's drawdown needs.
  • Root Cause: The pressure tank becomes waterlogged again within days of completing a drainage procedure.

    • Actionable Fix: The Schrader valve core is leaking air slowly, or the tank has a microscopic pinhole leak in the steel shell. Replace the valve core using a standard tire valve tool and spray soapy water around the welds to check for bubbling air leaks.
  • Root Cause: The pump continues to run constantly without building pressure in the tank.

    • Actionable Fix: The drain valve at the bottom of the tank is not fully seated, allowing air or water to bypass the system. Ensure the valve is wrenched completely closed, and verify that household faucets are entirely shut off to prevent ongoing demand.

Frequently Asked Questions



How often should I drain my well pressure tank?

You should drain and inspect your pressure tank at least once a year as part of standard home maintenance. Annual checks catch declining air charges early, preventing the pump short-cycling that leads to premature motor failure.



Can I drain a pressure tank without turning off the well pump?

No, you must always shut off the electrical power to the well pump before draining the tank. Leaving the pump powered on causes it to run continuously against zero head pressure, which generates excessive heat and destroys the pump impellers and motor.



What causes a pressure tank to become waterlogged?

A waterlogged tank occurs when the compressed air pocket inside the upper chamber escapes or becomes absorbed by the water over time. Without an air cushion to absorb hydraulic shock and maintain pressure, the tank fills entirely with water, forcing the pump to turn on every time a single drop of water is used.



How do I know what my air pre-charge pressure should be?

The correct air pre-charge must always be set exactly two PSI below your pressure switch cut-in setting. For instance, if your pump turns on at 30 PSI and off at 50 PSI, your tank bladder must be pressurized to 28 PSI when completely drained of water.



What should I do if my pressure tank won't hold air?

If you pump air into the Schrader valve and it immediately leaks out or forces water through the stem, the internal bladder is broken. A failed bladder means the tank has reached the end of its operational lifespan and requires complete replacement.

Protect your private water system investment by scheduling annual pressure tank maintenance and replacing failing components immediately.