The PureWick Female External Catheter system is a non-invasive urine management device designed to draw urine away from the body using low-pressure suction connected to a specialized pump. Proper placement requires precise anatomical alignment between the gluteal cleft and labia majora, strict adherence to hygienic protocols, and daily equipment maintenance to prevent skin breakdown and ensure continuous fluid dynamics.

Pre-Operation & Equipment Checklist for Female External Catheterization

Successful implementation of the PureWick system relies on proper environmental preparation, skin integrity maintenance, and a working understanding of low-pressure suction mechanics. This non-invasive urinary management tool acts as an alternative to indwelling Foley catheters, drastically reducing the risk of catheter-associated urinary tract infections (CAUTIs) when managed according to manufacturer specifications.



  • Essential gear, tools, and materials:

    • PureWick urine collection canister and lid with integrated suction tubing.
    • PureWick urine collection pump machine (capable of delivering continuous, regulated suction).
    • Individually packaged, single-use PureWick Female External Catheters (constructed of moisture-wicking materials).
    • Barrier cream or skin protectant (alcohol-free, zinc oxide-free options that do not compromise wicking fabric integrity).
    • Medical-grade disposable gloves and hypoallergenic cleansing wipes.
    • Measuring cylinder or container for monitoring output.
  • Mandatory prerequisite knowledge and clinical standards:

    • Patient must be in a lateral (side-lying), supine, or semi-Fowler position that allows clear visual or tactile access to the perineal region.
    • Suction pressure must be calibrated to run continuously while the device is in use; intermittent suction is not supported by the system architecture.
    • The catheter wick is strictly single-use and must be replaced every 8 to 12 hours or immediately upon soiling or structural degradation.
  • Estimated budget and operational duration benchmarks:

    • Initial equipment setup time: 5 to 10 minutes.
    • Routine daily consumable management: Replacement twice per 24-hour cycle.
    • Ongoing monthly supply cost: Variable based on insurance coverage, typically ranging from two to four boxes of wicks per month.

Step-by-Step Clinical Workflow for PureWick Application



Step 1: Hand Hygiene and Perineal Preparation

Begin by performing thorough hand hygiene with antimicrobial soap or an alcohol-based hand rub for at least 20 seconds, followed by the donning of clean disposable gloves. Assist the patient into a comfortable side-lying position with the knees slightly bent, as this posture naturally relaxes the gluteal muscles and exposes the external genitalia. Using a gentle, pH-balanced cleansing wipe, clean the perineal area from front to back to remove any residual bodily fluids or barrier films. Pat the skin completely dry with a soft towel; excess moisture impedes proper wicking function and increases the risk of moisture-associated skin damage (MASD).

Pro-Tip: Never use barrier creams containing petroleum, zinc oxide, or heavy oils directly on the skin where the wick makes contact, as these substances clog the porous material and ruin the wicking capability.



Step 2: Tubing and Machine Calibration

Inspect the PureWick collection system to ensure the collection canister is securely locked into the pump housing and the lid is airtight. Connect one end of the flexible connection tubing to the collection canister port and the other end securely to the plastic connector port at the base of the PureWick external catheter. Turn on the suction pump and verify that the system generates adequate negative pressure by occluding the distal end of the catheter momentarily with a gloved hand. Ensure the machine operates smoothly without unusual mechanical rattling or pressure drops.



Step 3: Anatomical Placement of the External Catheter

Part the patient's labia gently with one gloved hand to clearly identify the anatomical landmarks: the urinary meatus and the clitoris anteriorly, bound by the labia majora laterally. With your dominant hand, orient the PureWick catheter so the top edge rests softly just above the pubic bone, and the bottom contour sits precisely between the base of the clitoris and the anterior border of the anal sphincter. Tuck the lateral edges of the wick snugly inward between the labia majora and the labia minora. Ensure the soft wicking material makes direct, continuous contact with the urinary meatus without being inserted into the vagina or rectum.

Warning: The PureWick Female External Catheter is strictly designed for external use only. Never push, insert, or force any portion of the wick into the vaginal canal, urethra, or rectum.



Step 4: Securing Position and Verifying Suction

Instruct the patient to gently roll onto their back into a supine position, or maintain a semi-Fowler position with the head of the bed elevated no more than 30 degrees. The weight of the patient's body against the bed will naturally help stabilize the lateral placement of the wick, but you should visually or tactically verify that the device has not shifted out of alignment during the position change. Confirm that the suction machine is actively running and that urine can be observed flowing through the transparent connection tubing into the collection canister.



Step 5: Post-Application Monitoring and Maintenance

Check the alignment and skin condition beneath the PureWick catheter at least every two to four hours while the patient is awake. Empty the collection canister daily or whenever it reaches the maximum fill line, cleaning the container with warm soapy water or a mild disinfectant per manufacturer guidelines. Remove and replace the external catheter wick every 8 to 12 hours, or immediately if the patient has a bowel movement or if the material loses its structural integrity. Document output volume, patient tolerance, and skin integrity assessments in the medical record or home care log.


How the PureWick™ Male External Catheter Works

How the PureWick™ Male External Catheter Works

Technical Specifications and System Parameters Comparison



Parameter / Feature PureWick Female External Catheter Traditional Indwelling Foley Catheter Male Urinal / Standard Bedpan
Invasiveness Level Non-invasive (External placement only) Invasive (Urethral insertion with balloon retention) Non-invasive (External collection container)
CAUTI Risk Profile Extremely low (No internal urinary tract pathway) High (Direct bacterial ascent route via biofilm) Very low (External collection only)
Suction Requirement Continuous low-pressure active suction pump Gravity drainage via collection bag None (Passive collection)
Replacement Frequency Every 8 to 12 hours (Disposable wick) Every 30 days (Managed by licensed clinician) Cleaned after each individual use
Primary Clinical Indication Female urinary incontinence management Urinary retention, accurate output tracking, surgery Mobile or semi-mobile patients with voluntary control

Troubleshooting Common Operational Failures and Field Fixes



  • Problem: Urine is leaking around the edges of the catheter wick rather than draining into the tubing.

    • Root Cause: Incorrect anatomical placement, improper sizing, or patient shifting that misaligned the wick from the urinary meatus.
    • Actionable Fix: Re-evaluate the anatomical landmarks with the patient in a side-lying position. Ensure the top of the wick rests just above the pubic bone and the lateral edges are tucked securely between the labia. Verify that the suction pump is powered on and operating at full capacity.
  • Problem: The suction machine makes a hissing sound and urine fails to travel through the connection tubing.

    • Root Cause: Air leak within the system, loose tubing connections, or an unsealed collection canister lid.
    • Actionable Fix: Inspect every junction point from the catheter wick to the collection canister. Push all tubing connectors firmly together and ensure the canister lid gasket is seated flush without any pinched edges.
  • Problem: Skin irritation or maceration is developing in the perineal fold.

    • Root Cause: Prolonged exposure to moisture, residual soap from inadequate rinsing, or failure to change the wick at the recommended 8 to 12-hour interval.
    • Actionable Fix: Increase the frequency of wick changes. Ensure the perineal skin is thoroughly cleansed and patted 100 percent dry before applying a fresh catheter. Apply an approved moisture barrier wipe that does not interfere with wicking porosity.
  • Problem: The collection canister fills too rapidly or floods the machine filter.

    • Root Cause: High volume output exceeding standard canister capacity or failure to empty the container on a scheduled basis.
    • Actionable Fix: Empty the collection canister more frequently throughout the day and night. Inspect the hydrophobic inline filter on the machine lid; replace the filter immediately if moisture or fluid has breached the barrier to protect the internal motor.

Frequently Asked Questions



Can the PureWick catheter be worn overnight while sleeping?

Yes, the system is engineered for round-the-clock use, including overnight wear, provided the suction machine remains powered on continuously. The low-pressure pump safely manages urinary output while the patient rests in bed. Caregivers should ensure the tubing is unkinked and positioned to prevent accidental dislodgement during movement in sleep.



Is a doctor's prescription required to purchase the PureWick system?

In many jurisdictions and commercial insurance frameworks, a physician's prescription or order is required for reimbursement and purchase of the pump and consumable wicks. Check with your durable medical equipment (DME) provider or healthcare insurer to verify specific documentation requirements for coverage.



Can patients with mobility issues use PureWick independently?

The system generally requires caregiver assistance for proper placement, alignment, and removal, particularly for individuals with significant mobility limitations or cognitive impairments. However, patients with good upper body dexterity and tactile sensation can sometimes be trained to position and manage the device independently.



How often must the PureWick wick be changed?

The disposable wick must be replaced every 8 to 12 hours, or sooner if it becomes soiled with feces, saturated beyond capacity, or structurally compromised. Regular changes are vital for maintaining optimal fluid dynamics and protecting delicate perineal skin from irritation.



Can barrier creams be used with the PureWick system?

Only specialized, alcohol-free skin protectants that do not contain heavy oils, petroleum, or zinc oxide should be used. Standard barrier ointments clog the microscopic pores of the wicking fabric, rendering the system ineffective and increasing the risk of skin breakdown.

Optimize Your Continence Care Workflow Today

Integrate the PureWick system into your daily care routine to reduce skin breakdown risks and maintain dignified, non-invasive moisture management. Consult with a qualified healthcare professional today to evaluate your patient's specific anatomical needs and secure the appropriate equipment configuration.


How to Use & Place the PureWick™ Female External Catheter - All For One

How to Use & Place the PureWick™ Female External Catheter - All For One

Read also: Planning the Ultimate Fiesta? The Ultimate Guide to Finding Mariachi Bands for Hire Chicago for Your Next Celebration
close